免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人半胱氨酸蛋白酶抑制劑3(CST3)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1045
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human CST3(Cystatin 3) ELISA Kit
Reactivity: Human
Alternative Names: Cys-C; Cystatin C; Gamma Trace; Post-Gamma-Globulin; Neuroendocrine Basic Polypeptide; Amyloid Angiopathy And Cerebral Hemorrhage
Assay Type: Sandwich
Sensitivity: 0.67 ng/mL
Standard: 100 ng/mL
Detection Range: 1.57-100 ng/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids.
Assay Length: 3.5h
Research Area: Kidney biomarker;Urology;
Uniprot ID: P01034
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human CST3. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human CST3. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human CST3, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human CST3 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
100.00 2.218 2.058
50.00 1.964 1.804
25.00 1.528 1.368
12.50 0.899 0.739
6.25 0.577 0.417
3.13 0.351 0.191
1.57 0.264 0.104
0.00 0.160 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CST3 and the recovery rates were calculated by comparing the measured value to the expected amount of CST3 in samples.
Matrix Recovery range Average
serum(n=5) 79-91% 85%
EDTA plasma(n=5) 81-97% 89%
Heparin plasma(n=5) 84-99% 91%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CST3 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-92% 88-96% 87-98% 95-102%
EDTA plasma(n=5) 98-105% 96-103% 87-95% 83-92%
Heparin plasma(n=5) 95-104% 87-96% 89-101% 97-105%
關(guān)閉

在線咨詢(xún)

Online consultation

  • 在線咨詢(xún)
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢(xún)

微信掃一掃立即咨詢(xún)

關(guān)閉
黄平县| 罗江县| 石河子市| 昌邑市| 黑龙江省| 南江县| 五常市| 山东省| 珠海市| 金塔县| 怀仁县| 黄大仙区| 灵台县| 高青县| 正镶白旗| 临高县| 裕民县| 东乡| 磐安县| 兴海县| 莱芜市| 垣曲县| 尤溪县| 丰原市| 邵阳市| 冷水江市| 绥化市| 公安县| 泸西县| 永和县| 汉阴县| 临猗县| 改则县| 缙云县| 屏东县| 富裕县| 大埔区| 衡东县| 巴塘县| 金塔县| 杭锦后旗|