免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人骨橋素(OPN)酶聯(lián)免疫吸附檢測試劑盒
ELK1047
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview 文獻(xiàn)

Product name: Human OPN(Osteopontin) ELISA Kit
Reactivity: Human
Alternative Names: SPP1; BNSP; BSPI; ETA1; Secreted Phosphoprotein 1; Bone Sialoprotein I; Early T-Lymphocyte Activation 1; Nephropontin; Urinary stone protein; Uropontin
Assay Type: Sandwich
Sensitivity: 0.263 ng/mL
Standard: 40 ng/mL
Detection Range: 0.63-40 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Tumor immunity;Bone metabolism;
Uniprot ID: P10451
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human OPN. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human OPN. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human OPN, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human OPN in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
40.00 2.095 1.940
20.00 1.621 1.466
10.00 1.088 0.933
5.00 0.677 0.522
2.50 0.441 0.286
1.25 0.289 0.134
0.63 0.239 0.084
0.00 0.155 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant OPN and the recovery rates were calculated by comparing the measured value to the expected amount of OPN in samples.
Matrix Recovery range Average
serum(n=5) 80-95% 87%
EDTA plasma(n=5) 90-107% 98%
Heparin plasma(n=5) 87-99% 93%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of OPN and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 95-102% 97-105% 92-101% 85-92%
EDTA plasma(n=5) 88-97% 79-92% 85-93% 89-97%
Heparin plasma(n=5) 85-94% 97-103% 82-90% 92-101%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
新闻| 高邮市| 政和县| 莱芜市| 陇西县| 堆龙德庆县| 博罗县| 广东省| 松溪县| 柳林县| 潞城市| 洱源县| 石棉县| 平昌县| 从江县| 临邑县| 遂昌县| 宝丰县| 博罗县| 大方县| 柏乡县| 教育| 平谷区| 逊克县| 陈巴尔虎旗| 周宁县| 杭锦后旗| 包头市| 邵武市| 桃源县| 旬阳县| 桂林市| 达日县| 泸溪县| 休宁县| 茌平县| 民县| 观塘区| 江西省| 雷州市| 通辽市|