免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠骨橋素(OPN)酶聯(lián)免疫吸附檢測試劑盒
ELK1048
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Mouse OPN(Osteopontin) ELISA Kit
Reactivity: Mouse
Alternative Names: SPP1; BNSP; BSPI; ETA1; Secreted Phosphoprotein 1; Bone Sialoprotein I; Early T-Lymphocyte Activation 1; Nephropontin; Urinary stone protein; Uropontin
Assay Type: Sandwich
Sensitivity: 15 pg/mL
Standard: 2500 pg/mL
Detection Range: 39.07-2500 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Tumor immunity;Bone metabolism;
Uniprot ID: P10923
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse OPN. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse OPN. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse OPN, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse OPN in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (pg/mL) OD Corrected OD
2500.00 1.933 1.791
1250.00 1.573 1.431
625.00 1.275 1.133
312.50 0.923 0.781
156.25 0.601 0.459
78.13 0.340 0.198
39.07 0.244 0.102
0.00 0.142 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant OPN and the recovery rates were calculated by comparing the measured value to the expected amount of OPN in samples.
Matrix Recovery range Average
serum(n=5) 78-90% 84%
EDTA plasma(n=5) 85-97% 91%
Heparin plasma(n=5) 82-96% 89%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of OPN and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-92% 90-96% 79-102% 83-99%
EDTA plasma(n=5) 88-101% 86-92% 83-98% 96-103%
Heparin plasma(n=5) 85-94% 87-103% 81-95% 82-90%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
洛南县| 涞源县| 太原市| 富蕴县| 绩溪县| 大余县| 仁化县| 保德县| 吉木萨尔县| 于田县| 农安县| 拉萨市| 郯城县| 平顶山市| 泾川县| 开鲁县| 彭水| 江华| 紫金县| 凤凰县| 安多县| 伊金霍洛旗| 定安县| 延吉市| 兴和县| 奉节县| 吉林市| 凤庆县| 济南市| 瑞金市| 肇源县| 云南省| 昌宁县| 东乌珠穆沁旗| 文山县| 思南县| 平原县| 浮山县| 琼海市| 南宫市| 哈尔滨市|