免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人α1-酸性糖蛋白(a1AGP)酶聯(lián)免疫吸附檢測試劑盒
ELK1053
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human a1AGP(Alpha-1-Acid Glycoprotein) ELISA Kit
Reactivity: Human
Alternative Names: alpha1-AGP; AGP1; a1-AGP; ORM1; OMD 1; Orosomucoid 1
Assay Type: Sandwich
Sensitivity: 2.79 ng/mL
Standard: 400 ng/mL
Detection Range: 6.25-400 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Infection immunity;Hepatology;Gastroenterology;Immunodeficiency;
Uniprot ID: P02763
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human a1AGP. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human a1AGP. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human a1AGP, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human a1AGP in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
400.00 2.165 2.081
200.00 1.736 1.652
100.00 1.385 1.301
50.00 1.037 0.953
25.00 0.597 0.513
12.50 0.402 0.318
6.25 0.211 0.127
0.00 0.084 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant a1AGP and the recovery rates were calculated by comparing the measured value to the expected amount of a1AGP in samples.
Matrix Recovery range Average
serum(n=5) 82-94% 88%
EDTA plasma(n=5) 89-107% 98%
Heparin plasma(n=5) 85-97% 91%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of a1AGP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-92% 96-103% 87-98% 95-102%
EDTA plasma(n=5) 97-106% 86-92% 91-103% 89-97%
Heparin plasma(n=5) 85-94% 97-106% 89-97% 95-104%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
荆州市| 格尔木市| 余江县| 英超| 石狮市| 翁源县| 那曲县| 平远县| 陇南市| 昌宁县| 贺州市| 博白县| 修水县| 洛扎县| 武冈市| 抚松县| 澎湖县| 兴国县| 盘山县| 蒙城县| 淮滨县| 保康县| 文昌市| 长春市| 都昌县| 崇信县| 铜川市| 通河县| 潜江市| 鸡东县| 万盛区| 杂多县| 定州市| 清远市| 化州市| 宁津县| 富平县| 兴城市| 景德镇市| 东宁县| 沭阳县|