免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人結(jié)合珠蛋白(HP)酶聯(lián)免疫吸附檢測試劑盒
ELK1054
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview 文獻(xiàn)

Product name: Human HP(Haptoglobin) ELISA Kit
Reactivity: Human
Alternative Names: HP; Hp2-Alpha; Alpha-2-Macroglobulin; Zonulin; Hpt; Haptoglobin
Assay Type: Sandwich
Sensitivity: 2.87 ng/mL
Standard: 400 ng/mL
Detection Range: 6.25-400 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Infection immunity;Hematology;
Uniprot ID: P00738
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human HP. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human HP. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human HP, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human HP in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
400.00 2.119 1.967
200.00 1.896 1.744
100.00 1.649 1.497
50.00 1.005 0.853
25.00 0.634 0.482
12.50 0.428 0.276
6.25 0.238 0.086
0.00 0.152 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant HP and the recovery rates were calculated by comparing the measured value to the expected amount of HP in samples.
Matrix Recovery range Average
serum(n=5) 94-106% 100%
EDTA plasma(n=5) 80-97% 88%
Heparin plasma(n=5) 77-95% 86%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of HP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-102% 79-92% 87-103% 89-98%
EDTA plasma(n=5) 88-97% 91-98% 86-103% 79-91%
Heparin plasma(n=5) 85-104% 87-106% 83-92% 82-90%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
济阳县| 吉木萨尔县| 肃南| 上杭县| 嫩江县| 称多县| 福贡县| 清徐县| 吴江市| 阳城县| 河源市| 永顺县| 庐江县| 涡阳县| 潢川县| 慈溪市| 阿拉尔市| 花垣县| 宁阳县| 长沙市| 涿州市| 仁布县| 江华| 江门市| 游戏| 巢湖市| 凌云县| 砚山县| 汉中市| 英吉沙县| 高密市| 鹤庆县| 和林格尔县| 灵宝市| 福海县| 沈阳市| 蒙城县| 申扎县| 景宁| 涞水县| 保定市|