免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人補(bǔ)體成分3(C3)酶聯(lián)免疫吸附檢測試劑盒
ELK1059
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview 文獻(xiàn)

Product name: Human C3(Complement Component 3) ELISA Kit
Reactivity: Human
Alternative Names: ASP; CPAMD1; Complement Protein C3; C3 and PZP-like alpha-2-macroglobulin domain-containing protein 1; C3a anaphylatoxin; Acylation stimulating protein
Assay Type: Sandwich
Sensitivity: 2.8 ng/mL
Standard: 500 ng/mL
Detection Range: 7.82-500 ng/mL
Sample Type: serum, plasma and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;Infection immunity;Immune molecule;
Uniprot ID: P01024
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human C3. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human C3. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human C3, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human C3 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
500.00 1.997 1.898
250.00 1.586 1.487
125.00 1.277 1.178
62.50 0.935 0.836
31.25 0.596 0.497
15.63 0.379 0.280
7.82 0.197 0.098
0.00 0.099 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant C3 and the recovery rates were calculated by comparing the measured value to the expected amount of C3 in samples.
Matrix Recovery range Average
serum(n=5) 90-104% 97%
EDTA plasma(n=5) 80-97% 88%
Heparin plasma(n=5) 87-99% 93%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of C3 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 95-102% 83-96% 97-105% 85-97%
EDTA plasma(n=5) 88-97% 96-105% 81-96% 93-107%
Heparin plasma(n=5) 85-94% 87-96% 92-101% 82-95%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
汪清县| 城口县| 东辽县| 湘潭县| 新巴尔虎右旗| 连山| 沽源县| 旌德县| 龙陵县| 嘉兴市| 商水县| 陈巴尔虎旗| 和硕县| 贵定县| 宝鸡市| 中西区| 富宁县| 城口县| 开鲁县| 甘谷县| 新竹县| 广饶县| 崇文区| 开江县| 祁东县| 黄浦区| 灵台县| 大关县| 津市市| 凤台县| 新蔡县| 昌图县| 珲春市| 宿松县| 梓潼县| 大悟县| 和静县| 方山县| 西乌珠穆沁旗| 武鸣县| 平潭县|