免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠凝集素樣氧化低密度脂蛋白受體1(LOX1)酶聯(lián)免疫吸附檢測試劑盒
ELK1064
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Mouse LOX1(Lectin Like Oxidized Low Density Lipoprotein Receptor 1) ELISA Kit
Reactivity: Mouse
Alternative Names: OLR1; CLEC8A; SCARE1; Oxidized low-density lipoprotein receptor 1; C-type lectin domain family 8 member A; Lectin-like oxidized LDL receptor 1; Lectin-type oxidized LDL receptor 1
Assay Type: Sandwich
Sensitivity: 5.4 pg/mL
Standard: 800 pg/mL
Detection Range: 12.5-800 pg/mL
Sample Type: serum, plasma, tissue homogenates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;Metabolic pathway;Apoptosis;Endocrinology;Cardiovascular biology;Neuro science;
Uniprot ID: Q9EQ09
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse LOX1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse LOX1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse LOX1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse LOX1 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
800.00 2.169 2.041
400.00 1.782 1.654
200.00 1.224 1.096
100.00 0.868 0.740
50.00 0.538 0.410
25.00 0.342 0.214
12.50 0.251 0.123
0.00 0.128 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant LOX1 and the recovery rates were calculated by comparing the measured value to the expected amount of LOX1 in samples.
Matrix Recovery range Average
serum(n=5) 83-97% 90%
EDTA plasma(n=5) 78-92% 85%
Heparin plasma(n=5) 80-95% 87%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of LOX1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 95-102% 87-96% 78-92% 85-97%
EDTA plasma(n=5) 88-105% 86-92% 81-93% 79-97%
Heparin plasma(n=5) 85-102% 87-96% 92-101% 89-104%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
江阴市| 青阳县| 鄂伦春自治旗| 秀山| 佛冈县| 安阳县| 湖南省| 和田县| 视频| 温宿县| 施秉县| 合肥市| 延津县| 永泰县| 永靖县| 自治县| 南丹县| 监利县| 湘西| 长兴县| 双峰县| 和林格尔县| 东宁县| 河南省| 冷水江市| 宁乡县| 焦作市| 安达市| 礼泉县| 新昌县| 屏南县| 民乐县| 延边| 龙岩市| 民丰县| 页游| 渝北区| 沈阳市| 通河县| 新巴尔虎左旗| 黄浦区|