免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人成纖維細(xì)胞生長因子7(FGF7)酶聯(lián)免疫吸附檢測試劑盒
ELK1069
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human FGF7(Fibroblast Growth Factor 7) ELISA Kit
Reactivity: Human
Alternative Names: KGF; HBGF7; Keratinocyte Growth Factor; Heparin-binding growth factor 7
Assay Type: Sandwich
Sensitivity: 6.1 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Tumor immunity;Infection immunity;Developmental science;Pulmonology;Dermatology;
Uniprot ID: P21781
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human FGF7. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human FGF7. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human FGF7, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human FGF7 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
1000.00 2.121 2.020
500.00 1.542 1.441
250.00 1.106 1.005
125.00 0.812 0.711
62.50 0.521 0.420
31.25 0.332 0.231
15.63 0.211 0.110
0.00 0.101 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant FGF7 and the recovery rates were calculated by comparing the measured value to the expected amount of FGF7 in samples.
Matrix Recovery range Average
serum(n=5) 84-98% 91%
EDTA plasma(n=5) 80-96% 88%
Heparin plasma(n=5) 82-98% 90%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of FGF7 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 78-92% 83-96% 87-98% 95-102%
EDTA plasma(n=5) 90-97% 96-102% 91-103% 89-97%
Heparin plasma(n=5) 95-104% 87-96% 92-101% 82-90%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
封丘县| 海兴县| 成武县| 旌德县| 涿州市| 伊金霍洛旗| 昔阳县| 明光市| 大余县| 曲阜市| 永嘉县| 汝南县| 伊金霍洛旗| 肥东县| 南皮县| 红安县| 玛沁县| 武山县| 长沙市| 莫力| 宣化县| 松江区| 嘉鱼县| 镇康县| 壶关县| 瓦房店市| 屏南县| 北票市| 芦山县| 霞浦县| 班戈县| 南阳市| 维西| 五寨县| 德化县| 玉林市| 黄梅县| 梨树县| 涪陵区| 昭苏县| 民权县|