免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人α2-巨球蛋白(a2M)酶聯(lián)免疫吸附檢測試劑盒
ELK1070
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human a2M(Alpha-2-Macroglobulin) ELISA Kit
Reactivity: Human
Alternative Names: α2MG; α2Mg; CPAMD5; C3 and PZP-like alpha-2-macroglobulin domain-containing protein 5
Assay Type: Sandwich
Sensitivity: 0.35 ng/mL
Standard: 50 ng/mL
Detection Range: 0.79-50 ng/mL
Sample Type: serum, plasma, urine and other biological fluids
Assay Length: 3.5h
Research Area: Tumor immunity;Infection immunity;Hematology;
Uniprot ID: P01023
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human a2M. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human a2M. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human a2M, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human a2M in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
50.00 2.185 2.103
25.00 1.731 1.649
12.50 1.196 1.114
6.25 0.852 0.770
3.13 0.529 0.447
1.57 0.308 0.226
0.79 0.225 0.143
0.00 0.082 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant a2M and the recovery rates were calculated by comparing the measured value to the expected amount of a2M in samples.
Matrix Recovery range Average
serum(n=5) 79-93% 86%
EDTA plasma(n=5) 90-105% 97%
Heparin plasma(n=5) 86-99% 92%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of a2M and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-92% 89-96% 90-98% 87-98%
EDTA plasma(n=5) 88-99% 86-92% 89-103% 97-105%
Heparin plasma(n=5) 95-104% 87-96% 82-96% 89-103%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
霍邱县| 华蓥市| 兴化市| 建阳市| 桃园市| 苗栗市| 宿州市| 藁城市| 哈巴河县| 定边县| 三穗县| 监利县| 宁武县| 广元市| 永康市| 无锡市| 岳池县| 嘉峪关市| 任丘市| 博兴县| 堆龙德庆县| 抚州市| 龙山县| 兴隆县| 罗平县| 绥江县| 乌兰县| 宾川县| 佛坪县| 康马县| 洪泽县| 丰镇市| 章丘市| 洪洞县| 宁阳县| 岳池县| 建平县| 鲁甸县| 德钦县| 永寿县| 富平县|