免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠調(diào)節(jié)激活正常T-細(xì)胞表達(dá)分泌因子(RANTES)酶聯(lián)免疫吸附檢測試劑盒
ELK1082
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Mouse RANTES(Regulated On Activation In Normal T-Cell Expressed And Secreted) ELISA Kit
Reactivity: Mouse
Alternative Names: CCL5; SCYA5; SISd; EoCP; Chemokine C-C-Motif Ligand 5; Eosinophil Chemotactic Cytokine; T-cell Specific Protein p288; Small Inducible Cytokine Subfamily A(Cys-Cys)Member 5
Assay Type: Sandwich
Sensitivity: 32 pg/mL
Standard: 5000 pg/mL
Detection Range: 78.13-5000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Tumor immunity;Infection immunity;Immune molecule;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse RANTES. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse RANTES. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse RANTES, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse RANTES in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
5000.00 2.157 2.063
2500.00 1.647 1.553
1250.00 1.168 1.074
625.00 0.864 0.770
312.50 0.567 0.473
156.25 0.318 0.224
78.13 0.186 0.092
0.00 0.094 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant RANTES and the recovery rates were calculated by comparing the measured value to the expected amount of RANTES in samples.
Matrix Recovery range Average
serum(n=5) 82-95% 88%
EDTA plasma(n=5) 80-94% 87%
Heparin plasma(n=5) 95-107% 101%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of RANTES and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-103% 82-96% 87-105% 90-99%
EDTA plasma(n=5) 88-102% 86-92% 81-93% 79-87%
Heparin plasma(n=5) 79-94% 87-96% 85-98% 95-104%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
偃师市| 武穴市| 临夏市| 镇宁| 新竹市| 沙雅县| 宜章县| 长宁区| 兴海县| 襄汾县| 余干县| 通州区| 横山县| 娄烦县| 丽江市| 柯坪县| 新野县| 遂宁市| 绿春县| 武义县| 称多县| 德州市| 桂东县| 抚顺市| 和硕县| 玉溪市| 昔阳县| 绥江县| 东光县| 泽州县| 策勒县| 梓潼县| 玉龙| 漯河市| 普格县| 宕昌县| 齐齐哈尔市| 金湖县| 庆阳市| 藁城市| 利川市|