免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人低氧誘導(dǎo)因子1α(HIF1a)酶聯(lián)免疫吸附檢測試劑盒
ELK1603
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻(xiàn)

Product name: Human HIF1a(Hypoxia Inducible Factor 1 Alpha) ELISA Kit
Reactivity: Human
Alternative Names: HIF1-Alpha; HIF1-A; MOP1; PASD8; Basic Helix-Loop-Helix Transcription Factor; ARNT-interacting protein; Basic-helix-loop-helix-PAS protein MOP1; Class E basic helix-loop-helix protein 78
Assay Type: Sandwich
Sensitivity: 0.057 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Tumor immunity;Cardiovascular biology;Reproductive science;
Uniprot ID: Q16665
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human HIF1a. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human HIF1a. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human HIF1a, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human HIF1a in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.096 2.011
5.00 1.703 1.618
2.50 1.157 1.072
1.25 0.826 0.741
0.63 0.539 0.454
0.32 0.363 0.278
0.16 0.258 0.173
0.00 0.085 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant HIF1a and the recovery rates were calculated by comparing the measured value to the expected amount of HIF1a in samples.
Matrix Recovery range Average
serum(n=5) 83-95% 89%
EDTA plasma(n=5) 87-97% 90%
Heparin plasma(n=5) 81-95% 88%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of HIF1a and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-94% 87-96% 89-101% 82-90%
EDTA plasma(n=5) 78-92% 96-105% 87-98% 95-102%
Heparin plasma(n=5) 88-97% 91-103% 86-92% 89-97%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
广昌县| 凌云县| 南皮县| 平顺县| 左贡县| 保靖县| 治多县| 米林县| 西吉县| 崇阳县| 大冶市| 商河县| 寿光市| 满洲里市| 海阳市| 大英县| 那曲县| 红安县| 偃师市| 仁化县| 什邡市| 黑山县| 靖西县| 彭泽县| 吴堡县| 四川省| 巍山| 库伦旗| 湖北省| 聂拉木县| 孙吴县| 万源市| 昌图县| 新郑市| 浦县| 左贡县| 策勒县| 信阳市| 灯塔市| 镇康县| 揭西县|