免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人90kDa熱休克蛋白β1(HSP90b1)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1609
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human HSP90b1(Heat Shock Protein 90kDa Beta 1) ELISA Kit
Reactivity: Human
Alternative Names: HSP90-B1; ECGP; GP96; GRP94; TRA1; Glycoprotein 96; Tumor Rejection Antigen(gp96)1; 94 kDa glucose-regulated protein; Endoplasmin
Assay Type: Sandwich
Sensitivity: 0.127 ng/mL
Standard: 20 ng/mL
Detection Range: 0.32-20 ng/mL
Sample Type: serum, plasma, tissue homogenates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;Immune molecule;Developmental science;
Uniprot ID: P14625
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human HSP90b1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human HSP90b1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human HSP90b1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human HSP90b1 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
20.00 1.916 1.821
10.00 1.594 1.499
5.00 1.116 1.021
2.50 0.831 0.736
1.25 0.591 0.496
0.63 0.379 0.284
0.32 0.213 0.118
0.00 0.095 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant HSP90b1 and the recovery rates were calculated by comparing the measured value to the expected amount of HSP90b1 in samples.
Matrix Recovery range Average
serum(n=5) 90-103% 96%
EDTA plasma(n=5) 85-97% 91%
Heparin plasma(n=5) 82-95% 88%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of HSP90b1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-94% 87-101% 82-95% 82-93%
EDTA plasma(n=5) 85-102% 83-96% 87-98% 82-95%
Heparin plasma(n=5) 98-106% 86-99% 78-95% 89-97%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
临高县| 呈贡县| 枣强县| 河北区| 汝南县| 修文县| 视频| 怀仁县| 民县| 诏安县| 惠安县| 临洮县| 元谋县| 华阴市| 孟村| 通河县| 涞源县| 鹿泉市| 临湘市| 皮山县| 山西省| 咸丰县| 广东省| 乳山市| 龙岩市| 马公市| 巧家县| 通城县| 璧山县| 文水县| 鲁甸县| 湘潭县| 盐山县| 济阳县| 通海县| 达尔| 吴堡县| 永新县| 贡山| 新邵县| 九江市|