免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人血管緊張素原(AGT)酶聯(lián)免疫吸附檢測試劑盒
ELK1616
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human AGT(Angiotensinogen) ELISA Kit
Reactivity: Human
Alternative Names: ANHU; SERPINA8; Angiotensin; Renin Substrate; Serpin Peptidase Inhibitor,Clade A,Member 8(Alpha-1 Antiproteinase,Antitrypsin)
Assay Type: Sandwich
Sensitivity: 1.31 ng/mL
Standard: 200 ng/mL
Detection Range: 3.13-200 ng/mL
Sample Type: serum, plasma, urine, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cardiovascular biology;
Uniprot ID: P01019
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human AGT. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human AGT. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human AGT, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human AGT in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
200.00 1.908 1.804
100.00 1.628 1.524
50.00 1.142 1.038
25.00 0.855 0.751
12.50 0.591 0.487
6.25 0.345 0.241
3.13 0.228 0.124
0.00 0.104 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant AGT and the recovery rates were calculated by comparing the measured value to the expected amount of AGT in samples.
Matrix Recovery range Average
serum(n=5) 82-97% 89%
EDTA plasma(n=5) 87-95% 91%
Heparin plasma(n=5) 85-97% 91%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of AGT and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-96% 82-95% 93-102% 87-96%
EDTA plasma(n=5) 85-95% 85-96% 93-99% 87-101%
Heparin plasma(n=5) 88-100% 95-103% 89-97% 85-94%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
磴口县| 泰安市| 沽源县| 闵行区| 新疆| 比如县| 浠水县| 封丘县| 公主岭市| 扶沟县| 昌乐县| 中方县| 綦江县| 邢台市| 旬阳县| 新密市| 金门县| 崇义县| 峨眉山市| 枝江市| 西安市| 麦盖提县| 淮滨县| 夏邑县| 丽江市| 乐平市| 灵寿县| 水富县| 饶平县| 文安县| 青岛市| 增城市| 宁河县| 东台市| 焦作市| 河西区| 内丘县| 楚雄市| 静乐县| 嵊泗县| 泸水县|