免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠α1-酸性糖蛋白(a1AGP)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1621
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Mouse a1AGP(Alpha-1-Acid Glycoprotein) ELISA Kit
Reactivity: Mouse
Alternative Names: alpha1-AGP; AGP1; a1-AGP; ORM1; OMD 1; Orosomucoid 1
Assay Type: Sandwich
Sensitivity: 24.5 ng/mL
Standard: 4000 ng/mL
Detection Range: 62.5-4000 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Infection immunity;Hepatology;Gastroenterology;Immunodeficiency;
Uniprot ID: Q60590
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse a1AGP. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse a1AGP. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse a1AGP, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse a1AGP in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
4000.00 2.388 2.287
2000.00 1.658 1.557
1000.00 1.088 0.987
500.00 0.852 0.751
250.00 0.492 0.391
125.00 0.353 0.252
62.50 0.265 0.164
0.00 0.101 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant a1AGP and the recovery rates were calculated by comparing the measured value to the expected amount of a1AGP in samples.
Matrix Recovery range Average
serum(n=5) 77-95% 86%
EDTA plasma(n=5) 87-99% 93%
Heparin plasma(n=5) 78-92% 85%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of a1AGP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-94% 87-96% 92-101% 82-98%
EDTA plasma(n=5) 85-100% 80-97% 81-92% 87-103%
Heparin plasma(n=5) 82-93% 95-104% 82-96% 85-98%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
佛山市| 郧西县| 宁城县| 垫江县| 桐庐县| 宜昌市| 余干县| 黑山县| 昌江| 保山市| 丽水市| 横峰县| 广河县| 洪江市| 故城县| 秦皇岛市| 永丰县| 阜新市| 和平区| 明光市| 齐河县| 昌江| 丰宁| 建宁县| 绵阳市| 昌平区| 娄底市| 大丰市| 华安县| 三河市| 温宿县| 方城县| 穆棱市| 龙游县| 抚顺县| 延安市| 阿城市| 惠州市| 集贤县| 昌都县| 绥阳县|