免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

大鼠銅藍(lán)蛋白(CP)酶聯(lián)免疫吸附檢測試劑盒
ELK1622
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Rat CP(Ceruloplasmin) ELISA Kit
Reactivity: Rat
Alternative Names: CP2; CER; Caeruloplasmin; Ferroxidase; Oxygen Oxidoreductase
Assay Type: Sandwich
Sensitivity: 6.9 ng/mL
Standard: 1000 ng/mL
Detection Range: 15.63-1000 ng/mL
Sample Type: Serum, plasma and other biological fluids
Assay Length: 3.5h
Research Area: Metabolic pathway;Infection immunity;
Uniprot ID: P13635
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat CP. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat CP. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat CP, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat CP in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
1000.00 1.929 1.846
500.00 1.565 1.482
250.00 1.182 1.099
125.00 0.813 0.730
62.50 0.487 0.404
31.25 0.329 0.246
15.63 0.291 0.208
0.00 0.083 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CP and the recovery rates were calculated by comparing the measured value to the expected amount of CP in samples.
Matrix Recovery range Average
serum(n=5) 90-105% 97%
EDTA plasma(n=5) 97-105% 101%
Heparin plasma(n=5) 95-107% 101%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 95-104% 82-96% 92-105% 83-92%
EDTA plasma(n=5) 83-98% 88-97% 96-105% 86-92%
Heparin plasma(n=5) 89-97% 85-94% 79-96% 85-99%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
澳门| 常州市| 开远市| 武川县| 西充县| 峡江县| 曲靖市| 武城县| 安达市| 汕头市| 林甸县| 固镇县| 广宗县| 汕头市| 大洼县| 札达县| 莲花县| 临桂县| 凌海市| 兴安县| 普宁市| 崇州市| 美姑县| 抚顺县| 陆河县| 长岛县| 富川| 高陵县| 呼玛县| 贺州市| 界首市| 宜君县| 麟游县| 囊谦县| 焦作市| 沙坪坝区| 凌云县| 涞源县| 永福县| 康马县| 蕲春县|