免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人丙酮酸脫氫酶磷酸酶(PDP)酶聯(lián)免疫吸附檢測試劑盒
ELK1636
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human PDP(Pyruvate Dehydrogenase Phosphatase) ELISA Kit
Reactivity: Human
Alternative Names: PDP1; PDH; PPM2C; Protein Phosphatase 2C Magnesium-Dependent Catalytic Subunit; Pyruvate Dehyrogenase Phosphatase Catalytic Subunit 1
Assay Type: Sandwich
Sensitivity: 0.125 ng/mL
Standard: 20 ng/mL
Detection Range: 0.32-20 ng/mL
Sample Type: Tissue homogenates and other biological fluids.
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Metabolic pathway;Hepatology;
Uniprot ID: Q9P0J1
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human PDP. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human PDP. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human PDP, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human PDP in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
20.00 2.532 2.445
10.00 1.642 1.555
5.00 1.169 1.082
2.50 0.897 0.810
1.25 0.556 0.469
0.63 0.312 0.225
0.32 0.218 0.131
0.00 0.087 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant PDP and the recovery rates were calculated by comparing the measured value to the expected amount of PDP in samples.
Matrix Recovery range Average
serum(n=5) 94-105% 98%
EDTA plasma(n=5) 85-97% 91%
Heparin plasma(n=5) 78-95% 86%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of PDP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 79-93% 89-97% 85-94% 87-101%
EDTA plasma(n=5) 87-94% 85-96% 89-100% 85-96%
Heparin plasma(n=5) 85-94% 87-101% 86-97% 88-95%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
黄骅市| 和平县| 板桥市| 五大连池市| 凤翔县| 宣武区| 东安县| 岑巩县| 玉田县| 贵州省| 大连市| 榆树市| 台东市| 云安县| 江山市| 株洲县| 台东市| 资兴市| 尼木县| 富锦市| 西乌| 平遥县| 阜新市| 新郑市| 曲阜市| 黄石市| 运城市| 凤翔县| 肥西县| 盐源县| 抚顺县| 滁州市| 嘉鱼县| 晋州市| 通辽市| 安丘市| 土默特右旗| 乳山市| 邢台市| 怀宁县| 衡山县|