免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠蛋白酶激活受體2(PAR2)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1639
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Mouse PAR2(Protease Activated Receptor 2) ELISA Kit
Reactivity: Mouse
Alternative Names: F2RL1; F2-RL1; GPR11; PAR2; Coagulation Factor II(thrombin)receptor-Like 1; G-protein coupled receptor 11; Thrombin receptor-like 1
Assay Type: Sandwich
Sensitivity: 0.053 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: Tissue homogenates, cell lysates and other biological fluids.
Assay Length: 3.5h
Research Area: Signal transduction;
Uniprot ID: P55086
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse PAR2. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse PAR2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse PAR2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse PAR2 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.121 2.053
5.00 1.674 1.606
2.50 1.067 0.999
1.25 0.872 0.804
0.63 0.567 0.499
0.32 0.329 0.261
0.16 0.142 0.074
0.00 0.068 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant PAR2 and the recovery rates were calculated by comparing the measured value to the expected amount of PAR2 in samples.
Matrix Recovery range Average
serum(n=5) 78-90% 84%
EDTA plasma(n=5) 89-107% 98%
Heparin plasma(n=5) 87-99% 93%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of PAR2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 88-102% 87-102% 85-96% 87-101%
EDTA plasma(n=5) 86-93% 91-105% 87-99% 99-105%
Heparin plasma(n=5) 89-98% 83-103% 98-105% 92-101%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
长白| 抚州市| 黄龙县| 阳城县| 醴陵市| 永丰县| 镇安县| 邢台市| 五寨县| 张掖市| 岗巴县| 康乐县| 贵港市| 磐安县| 营口市| 雷波县| 拜城县| 六安市| 武城县| 康定县| 石家庄市| 莱芜市| 蓬溪县| 建始县| 将乐县| 松阳县| 祁门县| 黄大仙区| 长海县| 视频| 曲松县| 青州市| 龙州县| 新野县| 石屏县| 安塞县| 刚察县| 明星| 洪江市| 武鸣县| 盐池县|