免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

一步法人骨鈣素(OC)酶聯(lián)免疫吸附檢測試劑盒
ELK009ES
規格: 價(jià)格:
48T ¥2240.00
96T ¥3200.00

Overview

Product name: EasyStep Human OC(Osteocalcin) ELISA Kit
Reactivity: Human
Alternative Names: BGLAP; OT; BGP; Bone Gla Protein; Bone Gamma-Carboxyglutamate Protein; Gamma-carboxyglutamic acid-containing protein
Assay Type: Sandwich
Sensitivity: 0.14 ng/mL
Standard: 15 ng/mL
Detection Range: 0.23-15 ng/mL
Sample Type: Serum
Assay Length: 1.5h
Research Area: Metabolic pathway;Endocrinology;Hormone metabolism;Bone metabolism;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human OC, and the Human OC standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Human OC. After TMB substrate solution is added, only those wells that contain Human OC and HRP-conjugated antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human OC in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線(xiàn)

Concentration (ng/mL) OD Corrected OD
15.00 2.126 2.025
7.50 1.572 1.471
3.75 1.116 1.015
1.88 0.861 0.760
0.94 0.538 0.437
0.47 0.329 0.228
0.24 0.192 0.091
0.00 0.101 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant OC and the recovery rates were calculated by comparing the measured value to the expected amount of OC in samples.
Matrix Recovery range Average
serum(n=5) 87-99% 93%
EDTA plasma(n=5) 87-99% 93%
Heparin plasma(n=5) 81-95% 88%

線(xiàn)性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of OC and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 86-97% 88-95% 92-101% 87-98%
EDTA plasma(n=5) 78-92% 82-96% 86-99% 93-101%
Heparin plasma(n=5) 85-96% 86-98% 92-103% 87-93%

產(chǎn)品成分表

關(guān)閉

在線(xiàn)咨詢(xún)

Online consultation

  • 在線(xiàn)咨詢(xún)
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢(xún)

微信掃一掃立即咨詢(xún)

關(guān)閉
龙山县| 洱源县| 泰兴市| 曲阳县| 罗田县| 什邡市| 和田市| 称多县| 中江县| 金沙县| 神农架林区| 香港| 莱州市| 莆田市| 大化| 新绛县| 富裕县| 平度市| 乐业县| 巩义市| 宁德市| 德庆县| 沧州市| 自贡市| 秭归县| 武乡县| 枣庄市| 琼中| 青海省| 大洼县| 来凤县| 凤庆县| 靖西县| 宁国市| 新宾| 江北区| 文昌市| 湘阴县| 绿春县| 麻栗坡县| 平陆县|