免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

一步法人前列腺特異性膜抗原(PSMA)酶聯(lián)免疫吸附檢測試劑盒
ELK036ES
規格: 價(jià)格:
48T ¥2240.00
96T ¥3200.00

Overview

Product name: EasyStep Human PSMA(Prostate specific membrane antigen) ELISA Kit
Reactivity: Human
Alternative Names: Cell growth inhibiting protein 27; Cell growth-inhibiting gene 27 protein; FGCP; Folate hydrolase (prostate-specific membrane antigen) 1; Folate hydrolase 1
Assay Type: Sandwich
Sensitivity: 0.165 ng/mL
Standard: 40 ng/mL
Detection Range: 0.63-40 ng/mL
Sample Type: Serum, plasma
Assay Length: 1.5h
Research Area: Signal Transduction; Cancer; Metabolism
Uniprot ID: Q04609
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human PSMA, and the Human PSMA standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Human PSMA. After TMB substrate solution is added, only those wells that contain Human PSMA and HRP-conjugated antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human PSMA in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線(xiàn)

Concentration (ng/mL) OD Corrected OD
40.00 2.164 2.069
20.00 1.527 1.432
10.00 1.073 0.978
5.00 0.821 0.726
2.50 0.535 0.440
1.25 0.356 0.261
0.63 0.257 0.162
0.00 0.095 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant PSMA and the recovery rates were calculated by comparing the measured value to the expected amount of PSMA in samples.
Matrix Recovery range Average
serum(n=5) 90-105% 97%
EDTA plasma(n=5) 88-102% 95%
Heparin plasma(n=5) 80-92% 86%

線(xiàn)性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of PSMA and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 89-101% 87-98% 92-104% 82-96%
EDTA plasma(n=5) 85-94% 97-106% 79-91% 90-99%
Heparin plasma(n=5) 85-102% 81-96% 87-105% 83-92%

產(chǎn)品成分表

關(guān)閉

在線(xiàn)咨詢(xún)

Online consultation

  • 在線(xiàn)咨詢(xún)
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢(xún)

微信掃一掃立即咨詢(xún)

關(guān)閉
海南省| 论坛| 肇州县| 裕民县| 池州市| 略阳县| 双辽市| 临海市| 铜鼓县| 西乡县| 榆社县| 新疆| 阿勒泰市| 嘉义市| 雅安市| 铁岭县| 明溪县| 宿迁市| 玉林市| 安图县| 望江县| 玛纳斯县| 青田县| 长白| 沙雅县| 启东市| 藁城市| 宁蒗| 迁西县| 五峰| 涟源市| 宁国市| 禄丰县| 福建省| 红安县| 喜德县| 探索| 客服| 宁河县| 东光县| 咸阳市|