免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

一步法人中性粒細胞明膠酶關(guān)聯(lián)脂質(zhì)運載蛋白(NGAL)酶聯(lián)免疫吸附檢測試劑盒
ELK038ES
規格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: EasyStep Human NGAL(Neutrophil Gelatinase Associated Lipocalin) ELISA Kit
Reactivity: Human
Alternative Names: LCN2; p25; Lipocalin 2; Oncogene 24p3; 25 kDa alpha-2-microglobulin-related subunit of MMP-9; Siderocalin LCN2
Assay Type: Sandwich
Sensitivity: 5.6 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: Serum, plasma
Assay Length: 1.5h
Research Area: Infection immunity;Urology;
Uniprot ID: P80188
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human NGAL, and the Human NGAL standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Human NGAL. After TMB substrate solution is added, only those wells that contain Human NGAL and HRP-conjugated antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human NGAL in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線(xiàn)

Concentration (pg/mL) OD Corrected OD
1000.00 2.153 2.045
500.00 1.515 1.407
250.00 1.106 0.998
125.00 0.928 0.820
62.50 0.563 0.455
31.25 0.426 0.318
15.63 0.156 0.048
0.00 0.108 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant NGAL and the recovery rates were calculated by comparing the measured value to the expected amount of NGAL in samples.
Matrix Recovery range Average
serum(n=5) 94-105% 98%
EDTA plasma(n=5) 94-107% 100%
Heparin plasma(n=5) 82-95% 88%

線(xiàn)性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of NGAL and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 90-98% 85-92% 83-96% 93-102%
EDTA plasma(n=5) 85-94% 87-96% 82-93% 89-103%
Heparin plasma(n=5) 85-92% 83-101% 87-98% 79-92%

產(chǎn)品成分表

關(guān)閉

在線(xiàn)咨詢(xún)

Online consultation

  • 在線(xiàn)咨詢(xún)
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢(xún)

微信掃一掃立即咨詢(xún)

關(guān)閉
育儿| 河池市| 鹰潭市| 胶南市| 亳州市| 闸北区| 河源市| 烟台市| 麦盖提县| 山阴县| 大安市| 灵川县| 荃湾区| 衡水市| 汶上县| 习水县| 蒙自县| 云霄县| 太白县| 南江县| 多伦县| 农安县| 江城| 淄博市| 阳曲县| 米林县| 婺源县| 河池市| 东兰县| 建湖县| 启东市| 通山县| 秦皇岛市| 灯塔市| 普宁市| 博白县| 洪雅县| 邻水| 犍为县| 手游| 新乡市|