免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產品中心

人γ-氨基丁酸(gABA)酶聯(lián)免疫吸附檢測試劑盒
ELK0753
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview 文獻

Product name: Human gABA(Gamma-Aminobutyric Acid) ELISA Kit
Reactivity: Human
Alternative Names: 4-Aminobutyric Acid
Assay Type: Competitive Inhibition
Sensitivity: 14.6 pg/mL
Standard: 2000 pg/mL
Detection Range: 31.25-2000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 2.5h
Research Area: Signal transduction;Cardiovascular biology;Neuro science;Bone metabolism;
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Human gABA protein. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human gABA. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human gABA in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (pg/mL) OD Corrected OD
2000.00 0.174
1000.00 0.477
500.00 0.673
250.00 0.949
125.00 1.142
62.50 1.545
31.25 1.835
0.00 2.115

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant gABA and the recovery rates were calculated by comparing the measured value to the expected amount of gABA in samples.
Matrix Recovery range Average
serum(n=5) 83-95% 89%
EDTA plasma(n=5) 92-107% 99%
Heparin plasma(n=5) 85-99% 92%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of gABA and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-98% 85-93% 87-98% 89-103%
EDTA plasma(n=5) 87-98% 92-105% 95-104% 97-105%
Heparin plasma(n=5) 82-95% 98-105% 82-93% 95-102%
關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉
信宜市| 苏尼特左旗| 措美县| 海南省| 双流县| 漳平市| 彭水| 齐齐哈尔市| 阳高县| 丹江口市| 云霄县| 丽江市| 定州市| 和田市| 汨罗市| 宜丰县| 余庆县| 齐河县| 炉霍县| 响水县| 德庆县| 灵山县| 曲阜市| 莒南县| 古蔺县| 河曲县| 辽源市| 香格里拉县| 客服| 广灵县| 历史| 泸西县| 黄石市| 集安市| 泰来县| 昌平区| 安多县| 偃师市| 延长县| 中阳县| 辽中县|