免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

一步法人細胞程序性死亡蛋白1配體1(PDL1)酶聯(lián)免疫吸附檢測試劑盒
ELK084ES
規(guī)格: 價格:
64T ¥2240.00
112T ¥3200.00

Overview

Product name: EasyStep Human PDL1(Programmed Cell Death Protein 1 Ligand 1) ELISA Kit
Reactivity: Human
Alternative Names: CD274; PDL1; B7-H; B7H1; PD-L1; PDCD1L1; PDCD1-LG1; Programed Death Ligand 1; PDCD1LG1; Programmed Cell Death Protein 1 Ligand 1
Assay Type: Sandwich
Sensitivity: 1.23 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: Serum, plasma
Assay Length: 1.5h
Research Area: Signal transduction;Tumor immunity;Infection immunity;Immune molecule;Autoimmunity;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human PDL1, and the Human PDL1 standard plate wells that pre-coated using protein-related techniques are provided separately. Standard/Sample Diluent Buffer or samples are added to the appropriate microtiter plate wells ,then added a HRP-conjugated antibody specific to Human PDL1. After TMB substrate solution is added, only those wells that contain Human PDL1 and HRP-conjugated antibody will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human PDL1 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (pg/mL) OD Corrected OD
1000.00 2.052 1.949
500.00 1.509 1.406
250.00 1.285 1.182
125.00 0.765 0.662
62.50 0.493 0.390
31.25 0.312 0.209
15.63 0.186 0.083
0.00 0.103 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant PDL1 and the recovery rates were calculated by comparing the measured value to the expected amount of PDL1 in samples.
Matrix Recovery range Average
serum(n=5) 88-102% 95%
EDTA plasma(n=5) 79-97% 88%
Heparin plasma(n=5) 83-95% 89%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of PDL1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 89-97% 85-94% 79-96% 85-99%
EDTA plasma(n=5) 88-101% 86-92% 83-98% 96-103%
Heparin plasma(n=5) 85-94% 87-103% 81-95% 82-90%

產(chǎn)品成分表