免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠粒細(xì)胞集落刺激因子(GCSF)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1026
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Mouse GCSF(Colony Stimulating Factor 3, Granulocyte) ELISA Kit
Reactivity: Mouse
Alternative Names: CSF3; G-CSF; Granulocyte Colony Stimulating Factor; Pluripoietin; Filgrastim; Lenograstim
Assay Type: Sandwich
Sensitivity: 2.9 pg/mL
Standard: 500 pg/mL
Detection Range: 7.82-500 pg/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Hematology;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse GCSF. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse GCSF. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse GCSF, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse GCSF in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
500.00 1.961 1.874
250.00 1.487 1.400
125.00 0.924 0.837
62.50 0.629 0.542
31.25 0.428 0.341
15.63 0.218 0.131
7.82 0.190 0.103
0.00 0.087 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant GCSF and the recovery rates were calculated by comparing the measured value to the expected amount of GCSF in samples.
Matrix Recovery range Average
serum(n=5) 81-95% 88%
EDTA plasma(n=5) 86-99% 92%
Heparin plasma(n=5) 89-105% 97%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of GCSF and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-92% 95-103% 97-105% 93-102%
EDTA plasma(n=5) 98-105% 86-92% 91-103% 89-97%
Heparin plasma(n=5) 95-106% 87-96% 82-90% 92-101%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
怀来县| 无锡市| 隆昌县| 酒泉市| 汶川县| 资兴市| 区。| 肥城市| 洱源县| 手游| 万年县| 东台市| 奉节县| 蓝田县| 德格县| 汝南县| 扎鲁特旗| 温泉县| 宁德市| 开远市| 富源县| 永善县| 峨眉山市| 望城县| 靖安县| 京山县| 射洪县| 恩平市| 交口县| 通许县| 麦盖提县| 拜泉县| 临颍县| 蕉岭县| 吉木乃县| 临武县| 都昌县| 兴隆县| 千阳县| 乌兰浩特市| 奉新县|