免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人載脂蛋白A1(APOA1)酶聯(lián)免疫吸附檢測試劑盒
ELK1092
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human APOA1(Apolipoprotein A1) ELISA Kit
Reactivity: Human
Alternative Names: Apo-A1; ApoA-1 Milano; ProapoA-I; Proapolipoprotein A-I; Truncated apolipoprotein A-I
Assay Type: Sandwich
Sensitivity: 2.73 ng/mL
Standard: 400 ng/mL
Detection Range: 6.25-400 ng/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Metabolic pathway;Cardiovascular biology;Hepatology;
Uniprot ID: P02647
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human APOA1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human APOA1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human APOA1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human APOA1 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
400.00 2.121 2.038
200.00 1.757 1.674
100.00 1.346 1.263
50.00 0.892 0.809
25.00 0.514 0.431
12.50 0.354 0.271
6.25 0.199 0.116
0.00 0.083 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant APOA1 and the recovery rates were calculated by comparing the measured value to the expected amount of APOA1 in samples.
Matrix Recovery range Average
serum(n=5) 90-105% 97%
EDTA plasma(n=5) 85-97% 91%
Heparin plasma(n=5) 92-105% 98%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of APOA1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 78-92% 96-105% 87-98% 95-102%
EDTA plasma(n=5) 88-97% 91-103% 86-92% 89-97%
Heparin plasma(n=5) 93-106% 87-96% 92-99% 85-101%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
综艺| 融水| 浦北县| 乌兰县| 新巴尔虎右旗| 灵台县| 武义县| 辽中县| 拉萨市| 西华县| 津南区| 苏尼特左旗| 德钦县| 洪江市| 利辛县| 长寿区| 宜都市| 昭通市| 东台市| 天等县| 宾阳县| 聂荣县| 北安市| 扬中市| 赤壁市| 阿克陶县| 丰台区| 阆中市| 周至县| 长武县| 法库县| 唐河县| 山东| 河曲县| 冷水江市| 东乌| 迁安市| 叶城县| 察雅县| 黑山县| 五大连池市|