免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人胱天蛋白酶7(CASP7)酶聯(lián)免疫吸附檢測試劑盒
ELK1096
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human CASP7(Caspase 7) ELISA Kit
Reactivity: Human
Alternative Names: CMH1; ICE-LAP3; MCH3; Caspase 7 Apoptosis-Related Cysteine Peptidase; Cysteine Aspartate Protease 7; Cysteinyl Aspartate Specific Proteinases 7
Assay Type: Sandwich
Sensitivity: 0.057 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Apoptosis;
Uniprot ID: P55210
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human CASP7. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human CASP7. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human CASP7, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human CASP7 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.058 1.976
5.00 1.577 1.495
2.50 1.032 0.950
1.25 0.795 0.713
0.63 0.562 0.480
0.32 0.357 0.275
0.16 0.196 0.114
0.00 0.082 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CASP7 and the recovery rates were calculated by comparing the measured value to the expected amount of CASP7 in samples.
Matrix Recovery range Average
serum(n=5) 78-92% 85%
EDTA plasma(n=5) 88-106% 97%
Heparin plasma(n=5) 81-95% 88%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CASP7 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 78-92% 82-96% 86-99% 93-101%
EDTA plasma(n=5) 85-96% 86-98% 92-103% 87-93%
Heparin plasma(n=5) 81-94% 85-97% 93-102% 81-95%
關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉
甘谷县| 丰都县| 高阳县| 和林格尔县| 通江县| 常熟市| 岑巩县| 天长市| 清徐县| 马公市| 丰镇市| 同江市| 萨嘎县| 蒙阴县| 赣州市| 三河市| 兰溪市| 凤翔县| 海宁市| 西乌| 平遥县| 宜良县| 太康县| 夹江县| 静海县| 开江县| 永胜县| 巢湖市| 安宁市| 南城县| 湘西| 右玉县| 石首市| 客服| 资中县| 罗平县| 弥渡县| 永平县| 偏关县| 合江县| 凤阳县|