免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人皮膚T-細(xì)胞虜獲趨化因子(CTACK)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1107
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview 文獻(xiàn)

Product name: Human CTACK(Cutaneous T-Cell Attracting Chemokine) ELISA Kit
Reactivity: Human
Alternative Names: CCL27; ILC; SCYA27; ALP; Skinkine; ESkine; PESKY; CTAK; Chemokine(C-C-Motif)ligand 27; Small Inducible Cytokine Subfamily A Member 27; IL-11 R-alpha-locus chemokine
Assay Type: Sandwich
Sensitivity: 12.9 pg/mL
Standard: 2000 pg/mL
Detection Range: 31.25-2000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Tumor immunity;Infection immunity;Dermatology;
Uniprot ID: Q9Y4X3
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human CTACK. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human CTACK. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human CTACK, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human CTACK in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
2000.00 2.248 2.170
1000.00 1.687 1.609
500.00 0.990 0.912
250.00 0.614 0.536
125.00 0.386 0.308
62.50 0.236 0.158
31.25 0.155 0.077
0.00 0.078 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CTACK and the recovery rates were calculated by comparing the measured value to the expected amount of CTACK in samples.
Matrix Recovery range Average
serum(n=5) 96-107% 102%
EDTA plasma(n=5) 83-95% 89%
Heparin plasma(n=5) 85-99% 92%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CTACK and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-95% 85-96% 93-99% 87-101%
EDTA plasma(n=5) 88-100% 95-103% 89-97% 85-94%
Heparin plasma(n=5) 87-103% 97-105% 79-90% 87-96%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
集贤县| 澳门| 红原县| 夏津县| 宝应县| 轮台县| 景洪市| 商洛市| 长顺县| 阿拉善右旗| 赫章县| 桐城市| 沽源县| 瓮安县| 星子县| 札达县| 海淀区| 龙岩市| 平利县| 鹤庆县| 肥西县| 龙山县| 昌平区| 油尖旺区| 崇信县| 郸城县| 上高县| 刚察县| 瑞安市| 交口县| 邹城市| 海门市| 玛多县| 根河市| 新邵县| 康马县| 基隆市| 九龙坡区| 邹平县| 榆林市| 耒阳市|