免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人基質(zhì)金屬蛋白酶3(MMP3)酶聯(lián)免疫吸附檢測試劑盒
ELK1122
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview 文獻(xiàn)

Product name: Human MMP3(Matrix Metalloproteinase 3) ELISA Kit
Reactivity: Human
Alternative Names: SL1; STMY; STMY1; STR1; Progelatinase; Stromelysin 1; Transin-1
Assay Type: Sandwich
Sensitivity: 13.1 pg/mL
Standard: 2000 pg/mL
Detection Range: 31.25-2000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Tumor immunity;Infection immunity;Cardiovascular biology;
Uniprot ID: P08254
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human MMP3. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human MMP3. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human MMP3, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human MMP3 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
2000.00 2.132 2.047
1000.00 1.593 1.508
500.00 1.121 1.036
250.00 0.826 0.741
125.00 0.457 0.372
62.50 0.265 0.180
31.25 0.179 0.094
0.00 0.085 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant MMP3 and the recovery rates were calculated by comparing the measured value to the expected amount of MMP3 in samples.
Matrix Recovery range Average
serum(n=5) 88-102% 95%
EDTA plasma(n=5) 80-92% 86%
Heparin plasma(n=5) 90-105% 97%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of MMP3 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-91% 85-93% 89-97% 85-93%
EDTA plasma(n=5) 89-97% 85-94% 87-96% 85-97%
Heparin plasma(n=5) 85-94% 87-96% 92-101% 82-98%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
永济市| 汨罗市| 德庆县| 师宗县| 赞皇县| 澄迈县| 武功县| 涞源县| 建德市| 西吉县| 华池县| 崇信县| 新民市| 开化县| 安庆市| 涟源市| 雷州市| 日照市| 肇源县| 富源县| 社会| 铁岭县| 高邑县| 合阳县| 隆德县| 西和县| 柳林县| 太仆寺旗| 砀山县| 常山县| 青海省| 安吉县| 邵阳县| 潞西市| 张掖市| 抚顺市| 门头沟区| 神池县| 广饶县| 驻马店市| 呼图壁县|