免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人神經(jīng)生長因子(NGF)酶聯(lián)免疫吸附檢測試劑盒
ELK1173
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human NGF(Nerve Growth Factor) ELISA Kit
Reactivity: Human
Alternative Names: NGFB; Beta-NGF; HSAN5; NGF-B; Beta-Nerve Growth Factor
Assay Type: Sandwich
Sensitivity: 6.2 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Neuro science;
Uniprot ID: P01138
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human NGF. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human NGF. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human NGF, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human NGF in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
1000.00 2.038 1.965
500.00 1.527 1.454
250.00 1.123 1.050
125.00 0.726 0.653
62.50 0.435 0.362
31.25 0.386 0.313
15.63 0.225 0.152
0.00 0.073 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant NGF and the recovery rates were calculated by comparing the measured value to the expected amount of NGF in samples.
Matrix Recovery range Average
serum(n=5) 88-102% 95%
EDTA plasma(n=5) 90-105% 97%
Heparin plasma(n=5) 80-92% 86%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of NGF and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 96-105% 95-103% 95-103% 87-98%
EDTA plasma(n=5) 92-105% 83-92% 89-98% 85-94%
Heparin plasma(n=5) 86-102% 87-96% 89-98% 83-103%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
白山市| 革吉县| 滨州市| 长武县| 西昌市| 京山县| 四平市| 钟山县| 苍溪县| 年辖:市辖区| 海原县| 庆元县| 仲巴县| 古浪县| 永清县| 安西县| 汉寿县| 凤城市| 阳城县| 莆田市| 灌南县| 石狮市| 灵宝市| 金沙县| 定日县| 潮州市| 名山县| 永康市| 辛集市| 广汉市| 健康| 太谷县| 新津县| 和静县| 永平县| 肃宁县| 城市| 十堰市| 马龙县| 公主岭市| 介休市|