免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人轉(zhuǎn)化生長因子α(TGFa)酶聯(lián)免疫吸附檢測試劑盒
ELK1184
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human TGFa(Transforming Growth Factor Alpha) ELISA Kit
Reactivity: Human
Alternative Names: TGF Alpha; ETGF; TGF-A; Protransforming Growth Factor alpha; EGF-Like TGF
Assay Type: Sandwich
Sensitivity: 6 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Tumor immunity;Infection immunity;
Uniprot ID: P01135
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human TGFa. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human TGFa. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human TGFa, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human TGFa in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
1000.00 2.058 1.990
500.00 1.587 1.519
250.00 1.069 1.001
125.00 0.797 0.729
62.50 0.532 0.464
31.25 0.364 0.296
15.63 0.206 0.138
0.00 0.068 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant TGFa and the recovery rates were calculated by comparing the measured value to the expected amount of TGFa in samples.
Matrix Recovery range Average
serum(n=5) 93-105% 99%
EDTA plasma(n=5) 84-93% 89%
Heparin plasma(n=5) 81-103% 87%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of TGFa and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 91-99% 83-89% 88-104% 97-103%
EDTA plasma(n=5) 85-95% 79-96% 89-101% 85-97%
Heparin plasma(n=5) 86-96% 93-104% 89-97% 85-94%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
白城市| 宁远县| 肥乡县| 呼伦贝尔市| 东源县| 时尚| 航空| 江永县| 乌拉特前旗| 宣城市| 页游| 宣恩县| 维西| 津市市| 恩施市| 台南市| 金门县| 湘潭市| 罗城| 荆门市| 邢台县| 陈巴尔虎旗| 卓资县| 新邵县| 高碑店市| 石林| 临汾市| 九龙县| 罗甸县| 嘉义市| 乌拉特中旗| 清徐县| 关岭| 大关县| 巴彦县| 长子县| 海门市| 连城县| 阳谷县| 日土县| 老河口市|