免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人組織金屬蛋白酶抑制因子4(TIMP4)酶聯(lián)免疫吸附檢測試劑盒
ELK1189
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human TIMP4(Tissue Inhibitors Of Metalloproteinase 4) ELISA Kit
Reactivity: Human
Alternative Names: TIMP Metallopeptidase Inhibitor 4; Tissue Inhibitor of Metalloproteinases 4
Assay Type: Sandwich
Sensitivity: 0.058 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates and other biological fluids.
Assay Length: 3.5h
Research Area: Tumor immunity;Cardiovascular biology;
Uniprot ID: Q99727
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human TIMP4. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human TIMP4. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human TIMP4, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human TIMP4 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
10.00 1.997 1.914
5.00 1.579 1.496
2.50 1.043 0.960
1.25 0.792 0.709
0.63 0.651 0.568
0.32 0.301 0.218
0.16 0.232 0.149
0.00 0.083 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant TIMP4 and the recovery rates were calculated by comparing the measured value to the expected amount of TIMP4 in samples.
Matrix Recovery range Average
serum(n=5) 78-90% 84%
EDTA plasma(n=5) 95-107% 101%
Heparin plasma(n=5) 85-98% 91%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of TIMP4 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 78-92% 83-96% 95-107% 87-102%
EDTA plasma(n=5) 88-102% 86-97% 89-97% 79-95%
Heparin plasma(n=5) 81-94% 96-105% 92-103% 82-96%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
东辽县| 广元市| 武乡县| 宜川县| 通河县| 黔东| 玉山县| 阿坝县| 鞍山市| 板桥市| 普宁市| 南平市| 宁蒗| 光泽县| 英德市| 达州市| 广丰县| 南涧| 吴桥县| 阳山县| 平果县| 门头沟区| 明溪县| 元阳县| 绍兴县| 嵩明县| 会同县| 娄底市| 二连浩特市| 铁力市| 霸州市| 邯郸市| 台安县| 丹凤县| 卫辉市| 农安县| 伽师县| 建湖县| 常山县| 钟祥市| 惠东县|