免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人血管內(nèi)皮生長(zhǎng)因子121(VEGF121)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1193
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human VEGF121(Vascular Endothelial Growth Factor 121) ELISA Kit
Reactivity: Human
Alternative Names: Vascular Endothelial Growth Factor 121
Assay Type: Sandwich
Sensitivity: 6.7 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Signal transduction;Tumor immunity;Infection immunity;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human VEGF121. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human VEGF121. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human VEGF121, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human VEGF121 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
1000.00 1.952 1.884
500.00 1.387 1.319
250.00 0.939 0.871
125.00 0.752 0.684
62.50 0.553 0.485
31.25 0.329 0.261
15.63 0.142 0.074
0.00 0.068 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant VEGF121 and the recovery rates were calculated by comparing the measured value to the expected amount of VEGF121 in samples.
Matrix Recovery range Average
serum(n=5) 82-95% 88%
EDTA plasma(n=5) 80-93% 86%
Heparin plasma(n=5) 95-108% 101%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of VEGF121 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 80-92% 86-102% 87-103% 85-101%
EDTA plasma(n=5) 82-93% 96-105% 87-98% 85-97%
Heparin plasma(n=5) 82-94% 85-96% 78-90% 91-99%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
肇庆市| 盐源县| 伊吾县| 探索| 河东区| 徐州市| 巩留县| 那曲县| 东阳市| 门头沟区| 巴东县| 武威市| 法库县| 上高县| 新竹县| 台州市| 米林县| 乳源| 通道| 防城港市| 灌阳县| 白河县| 夏邑县| 孙吴县| 通州市| 石柱| 蕲春县| 祥云县| 济源市| 大荔县| 南平市| 奉新县| 卢氏县| 体育| 共和县| 鄂托克旗| 扬中市| 巴里| 紫云| 孟州市| 盘锦市|