免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人髓細(xì)胞觸發(fā)受體1(TREM1)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1199
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human TREM1(Triggering Receptor Expressed On Myeloid Cells 1) ELISA Kit
Reactivity: Human
Alternative Names: CD354; Triggering Receptor Expressed On Monocytes-1
Assay Type: Sandwich
Sensitivity: 5.8 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Infection immunity;
Uniprot ID: Q9NP99
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human TREM1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human TREM1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human TREM1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human TREM1 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
1000.00 2.035 1.953
500.00 1.633 1.551
250.00 1.188 1.106
125.00 0.728 0.646
62.50 0.632 0.550
31.25 0.335 0.253
15.63 0.219 0.137
0.00 0.082 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant TREM1 and the recovery rates were calculated by comparing the measured value to the expected amount of TREM1 in samples.
Matrix Recovery range Average
serum(n=5) 82-95% 88%
EDTA plasma(n=5) 95-107% 101%
Heparin plasma(n=5) 90-105% 97%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of TREM1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 81-93% 78-91% 87-98% 95-107%
EDTA plasma(n=5) 88-103% 86-97% 87-102% 89-101%
Heparin plasma(n=5) 85-94% 79-96% 92-105% 91-99%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
西林县| 宣恩县| 海盐县| 库伦旗| 津市市| 乌什县| 丽水市| 新乐市| 北海市| 双辽市| 淮南市| 仁寿县| 玉溪市| 龙井市| 娄底市| 故城县| 福贡县| 巩留县| 精河县| 崇文区| 东莞市| 田阳县| 海南省| 邓州市| 玛多县| 会理县| 镇雄县| 泌阳县| 来宾市| 泰顺县| 南召县| 贡嘎县| 东兰县| 府谷县| 高雄县| 城市| 施秉县| 攀枝花市| 永仁县| 都江堰市| 武平县|