免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人腸脂肪酸結(jié)合蛋白(IFABP/FABP2)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1264
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human IFABP/FABP2(Intestinal Fatty Acid Binding Protein) ELISA Kit
Reactivity: Human
Alternative Names: FABPI; IFABP; I-FABP; Intestinal-type fatty acid-binding protein; FABP2; Fatty Acid Binding Protein 2, Intestinal
Assay Type: Sandwich
Sensitivity: 0.061 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Metabolic pathway;Tumor immunity;Endocrinology;Cardiovascular biology;
Uniprot ID: P12104
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human IFABP/FABP2. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human IFABP/FABP2. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human IFABP/FABP2, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human IFABP/FABP2 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.035 1.928
5.00 1.593 1.486
2.50 1.183 1.076
1.25 0.752 0.645
0.63 0.546 0.439
0.32 0.354 0.247
0.16 0.232 0.125
0.00 0.107 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant IFABP/FABP2 and the recovery rates were calculated by comparing the measured value to the expected amount of IFABP/FABP2 in samples.
Matrix Recovery range Average
serum(n=5) 82-95% 88%
EDTA plasma(n=5) 80-95% 87%
Heparin plasma(n=5) 86-99% 92%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of IFABP/FABP2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-98% 92-105% 95-107% 82-96%
EDTA plasma(n=5) 81-94% 93-107% 93-102% 91-105%
Heparin plasma(n=5) 89-98% 81-94% 96-105% 92-103%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
东港市| 仁化县| 南郑县| 六安市| 宜兴市| 湘潭县| 鹤岗市| 正定县| 库伦旗| 台山市| 修武县| 潮安县| 奇台县| 安徽省| 土默特左旗| 徐闻县| 额济纳旗| 金阳县| 土默特左旗| 丰城市| 桐梓县| 景泰县| 石楼县| 泽州县| 延寿县| 彰武县| 禄丰县| 张掖市| 武威市| 上蔡县| 成武县| 蕉岭县| 德令哈市| 东海县| 县级市| 林周县| 东丽区| 中宁县| 肥城市| 马边| 吴堡县|