免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人P選擇素(SELP)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1274
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human SELP(Selectin, Platelet) ELISA Kit
Reactivity: Human
Alternative Names: CD62P; P-Selectin; PSEL; GMP140; LECAM3; GRMP; GMRP; PADGEM; Leukocyte-endothelial cell adhesion molecule 3; Platelet activation dependent granule-external membrane
Assay Type: Sandwich
Sensitivity: 34 pg/mL
Standard: 5000 pg/mL
Detection Range: 78.13-5000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: CD & Adhesion molecule;Tumor immunity;Infection immunity;
Uniprot ID: P16109
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human SELP. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human SELP. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human SELP, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human SELP in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
5000.00 1.948 1.844
2500.00 1.593 1.489
1250.00 1.116 1.012
625.00 0.705 0.601
312.50 0.468 0.364
156.25 0.308 0.204
78.13 0.256 0.152
0.00 0.104 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant SELP and the recovery rates were calculated by comparing the measured value to the expected amount of SELP in samples.
Matrix Recovery range Average
serum(n=5) 82-95% 88%
EDTA plasma(n=5) 95-107% 101%
Heparin plasma(n=5) 87-99% 93%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of SELP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 89-101% 79-92% 82-93% 83-97%
EDTA plasma(n=5) 82-103% 81-91% 85-101% 81-90%
Heparin plasma(n=5) 85-98% 81-96% 87-98% 92-103%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
苏尼特左旗| 平顶山市| 松阳县| 阳江市| 河东区| 昔阳县| 太白县| 西乌珠穆沁旗| 波密县| 扶风县| 淄博市| 铜鼓县| 武强县| 阳曲县| 嘉义市| 庆云县| 土默特右旗| 堆龙德庆县| 长沙市| 兖州市| 蓬安县| 和平区| 乐清市| 鹤峰县| 开平市| 荆州市| 宁明县| 望都县| 湖北省| 桓仁| 万盛区| 鲁山县| 清原| 马边| 绥芬河市| 武宁县| 渭南市| 聂拉木县| 嘉禾县| 白城市| 那坡县|