免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人上皮中性粒細(xì)胞激活肽78(ENA78)酶聯(lián)免疫吸附檢測試劑盒
ELK1277
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview 文獻(xiàn)

Product name: Human ENA78(Epithelial Neutrophil Activating Peptide 78) ELISA Kit
Reactivity: Human
Alternative Names: CXCL5; SCYB5; Chemokine C-X-C-Motif Ligand 5; Small Inducible Cytokine Subfamily B(Cys-X-Cys),Member 5; Neutrophil-activating peptide ENA-78
Assay Type: Sandwich
Sensitivity: 0.055 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Infection immunity;
Uniprot ID: P42830
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human ENA78. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human ENA78. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human ENA78, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human ENA78 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
10.00 1.842 1.759
5.00 1.593 1.510
2.50 1.175 1.092
1.25 0.886 0.803
0.63 0.595 0.512
0.32 0.339 0.256
0.16 0.215 0.132
0.00 0.083 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant ENA78 and the recovery rates were calculated by comparing the measured value to the expected amount of ENA78 in samples.
Matrix Recovery range Average
serum(n=5) 87-99% 93%
EDTA plasma(n=5) 85-99% 92%
Heparin plasma(n=5) 93-107% 100%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of ENA78 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 92-103% 81-92% 78-87% 91-99%
EDTA plasma(n=5) 92-104% 93-99% 87-95% 82-93%
Heparin plasma(n=5) 88-96% 90-101% 93-102% 85-94%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
马鞍山市| 芜湖县| 信丰县| 兴城市| 宜兴市| 苏尼特左旗| 余干县| 福鼎市| 体育| 宜春市| 青阳县| 邢台市| 滕州市| 沐川县| 瑞昌市| 张家界市| 阿瓦提县| 巴林右旗| 县级市| 民勤县| 长春市| 盐池县| 大足县| 犍为县| 罗江县| 应用必备| 云霄县| 静海县| 云阳县| 怀远县| 微山县| 炉霍县| 天柱县| 黄梅县| 锡林郭勒盟| 奉新县| 井冈山市| 会泽县| 南靖县| 电白县| 奉贤区|