免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠肌酸激酶MB同工酶(CKMB)酶聯(lián)免疫吸附檢測試劑盒
ELK1286
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview 文獻(xiàn)

Product name: Mouse CKMB(Creatine Kinase MB Isoenzyme) ELISA Kit
Reactivity: Mouse
Alternative Names: CK2; CK-MB; Creatine Kinase,Muscle/Brain
Assay Type: Sandwich
Sensitivity: 0.29 ng/mL
Standard: 50 ng/mL
Detection Range: 0.79-50 ng/mL
Sample Type: serum, plasma, tissue homogenates and other biological fluids
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Cardiovascular biology;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse CKMB. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse CKMB. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse CKMB, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse CKMB in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
50.00 1.916 1.829
25.00 1.394 1.307
12.50 0.993 0.906
6.25 0.796 0.709
3.13 0.473 0.386
1.57 0.327 0.240
0.79 0.214 0.127
0.00 0.087 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CKMB and the recovery rates were calculated by comparing the measured value to the expected amount of CKMB in samples.
Matrix Recovery range Average
serum(n=5) 84-97% 90%
EDTA plasma(n=5) 82-94% 88%
Heparin plasma(n=5) 81-97% 89%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CKMB and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 98-102% 86-92% 81-93% 89-98%
EDTA plasma(n=5) 85-104% 97-106% 86-97% 92-99%
Heparin plasma(n=5) 85-93% 87-96% 79-91% 95-103%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
文水县| 呼和浩特市| 阿坝县| 罗山县| 三穗县| 浪卡子县| 桃园市| 岐山县| 改则县| 麻城市| 津南区| 云龙县| 德惠市| 通许县| 克什克腾旗| 昭苏县| 马边| 沙河市| 灵武市| 长汀县| 涞源县| 德格县| 汾西县| 汉沽区| 交口县| 珠海市| 上饶县| 屏东县| 鲁山县| 江孜县| 北安市| 紫金县| 嘉黎县| 贞丰县| 集安市| 玉山县| 比如县| 遂平县| 永昌县| 安新县| 乳山市|