免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人甲胎蛋白(aFP)酶聯(lián)免疫吸附檢測試劑盒
ELK1301
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human aFP(Alpha-Fetoprotein) ELISA Kit
Reactivity: Human
Alternative Names: A-FP; FETA; HPAFP; Alpha-Fetoglobulin; Alpha-1-fetoprotein
Assay Type: Sandwich
Sensitivity: 0.25 ng/mL
Standard: 50 ng/mL
Detection Range: 0.79-50 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Tumor immunity;Hepatology;
Uniprot ID: P02771
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human aFP. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human aFP. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human aFP, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human aFP in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
50.00 2.027 1.940
25.00 1.487 1.400
12.50 1.043 0.956
6.25 0.828 0.741
3.13 0.508 0.421
1.57 0.340 0.253
0.79 0.190 0.103
0.00 0.087 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant aFP and the recovery rates were calculated by comparing the measured value to the expected amount of aFP in samples.
Matrix Recovery range Average
serum(n=5) 87-99% 93%
EDTA plasma(n=5) 78-92% 85%
Heparin plasma(n=5) 85-99% 92%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of aFP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 97-105% 86-98% 84-93% 89-102%
EDTA plasma(n=5) 85-94% 87-105% 92-101% 79-90%
Heparin plasma(n=5) 85-102% 82-96% 87-98% 78-92%
關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉
馆陶县| 徐州市| 华蓥市| 赣榆县| 浦江县| 盖州市| 石狮市| 高要市| 芷江| 沙田区| 彰武县| 独山县| 辉南县| 稻城县| 长沙市| 临海市| 嘉峪关市| 肥东县| 郧西县| 沛县| 应用必备| 盐亭县| 德令哈市| 乌拉特后旗| 邳州市| 清流县| 广饶县| 东乡族自治县| 仁寿县| 扎赉特旗| 武邑县| 康保县| 内丘县| 白山市| 博湖县| 来凤县| 治多县| 锡林浩特市| 蓬莱市| 鹤壁市| 容城县|