免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠髓細(xì)胞觸發(fā)受體1(TREM1)酶聯(lián)免疫吸附檢測試劑盒
ELK1305
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Mouse TREM1(Triggering Receptor Expressed On Myeloid Cells 1) ELISA Kit
Reactivity: Mouse
Alternative Names: CD354; Triggering Receptor Expressed On Monocytes-1
Assay Type: Sandwich
Sensitivity: 6.7 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Infection immunity;
Uniprot ID: Q9JKE2
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse TREM1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse TREM1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse TREM1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse TREM1 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
1000.00 2.105 2.034
500.00 1.609 1.538
250.00 1.147 1.076
125.00 0.738 0.667
62.50 0.536 0.465
31.25 0.357 0.286
15.63 0.192 0.121
0.00 0.071 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant TREM1 and the recovery rates were calculated by comparing the measured value to the expected amount of TREM1 in samples.
Matrix Recovery range Average
serum(n=5) 78-92% 85%
EDTA plasma(n=5) 92-107% 99%
Heparin plasma(n=5) 87-99% 93%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of TREM1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 98-105% 86-92% 87-93% 95-103%
EDTA plasma(n=5) 91-98% 79-93% 92-101% 82-90%
Heparin plasma(n=5) 85-92% 80-96% 87-98% 95-102%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
商南县| 喀喇沁旗| 陇南市| 柳州市| 德化县| 西吉县| 福鼎市| 罗江县| 黔东| 定南县| 平乡县| 合川市| 原阳县| 陇西县| 平阳县| 大冶市| 宁海县| 繁峙县| 洛浦县| 渭源县| 梁山县| 神木县| 宜黄县| 西丰县| 南和县| 马鞍山市| 乌兰县| 霍山县| 利辛县| 开化县| 潜山县| 梅州市| 宝山区| 吉林省| 越西县| 阳谷县| 辽源市| 梧州市| 涞源县| 阿城市| 开原市|