免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

大鼠促卵泡素(FSH)酶聯(lián)免疫吸附檢測試劑盒
ELK1315
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview 文獻(xiàn)

Product name: Rat FSH(Follicle Stimulating Hormone) ELISA Kit
Reactivity: Rat
Alternative Names: FSH-B; FSH-beta
Assay Type: Sandwich
Sensitivity: 0.71 mIU/mL
Standard: 100 mIU/mL
Detection Range: 1.57-100 mIU/mL
Sample Type: serum, plasma and other biological fluids
Assay Length: 3.5h
Research Area: Endocrinology;Reproductive science;Genetic science;Hormone metabolism;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat FSH. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat FSH. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat FSH, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat FSH in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (mIU/mL) OD Corrected OD
100.00 2.328 2.225
50.00 1.663 1.560
25.00 1.273 1.170
12.50 0.821 0.718
6.25 0.558 0.455
3.13 0.340 0.237
1.57 0.238 0.135
0.00 0.103 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant FSH and the recovery rates were calculated by comparing the measured value to the expected amount of FSH in samples.
Matrix Recovery range Average
serum(n=5) 90-105% 97%
EDTA plasma(n=5) 81-97% 89%
Heparin plasma(n=5) 85-99% 92%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of FSH and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 82-94% 85-96% 78-90% 91-99%
EDTA plasma(n=5) 85-94% 87-101% 89-99% 85-95%
Heparin plasma(n=5) 86-99% 93-107% 85-94% 87-101%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
剑阁县| 敦化市| 云阳县| 拉萨市| 巨野县| 天长市| 彰武县| 梁平县| 武汉市| 岳池县| 闸北区| 乌拉特前旗| 卫辉市| 安远县| 花莲市| 富锦市| 文化| 凭祥市| 无极县| 淮安市| 万安县| 唐海县| 临泽县| 阿图什市| 余姚市| 交口县| 铁力市| 金华市| 阿图什市| 博爱县| 蒙阴县| 壤塘县| 灵石县| 同江市| 三门峡市| 卫辉市| 广安市| 丹寨县| 莲花县| 黔西县| 宜君县|