免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠干擾素γ誘導(dǎo)單核因子(MIg)酶聯(lián)免疫吸附檢測試劑盒
ELK1336
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Mouse MIg(Monokine Induced By Interferon Gamma) ELISA Kit
Reactivity: Mouse
Alternative Names: CXCL9; CMK; Humig; MI-G; SCYB9; Crg-10; Chemokine (C-X-C motif) ligand 9; Small-inducible cytokine B9; Gamma-interferon-induced monokine
Assay Type: Sandwich
Sensitivity: 6.3 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Infection immunity;
Uniprot ID: P18340
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse MIg. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse MIg. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse MIg, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse MIg in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
1000.00 2.119 2.022
500.00 1.706 1.609
250.00 1.149 1.052
125.00 0.905 0.808
62.50 0.634 0.537
31.25 0.427 0.330
15.63 0.215 0.118
0.00 0.097 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant MIg and the recovery rates were calculated by comparing the measured value to the expected amount of MIg in samples.
Matrix Recovery range Average
serum(n=5) 82-96% 87%
EDTA plasma(n=5) 86-97% 92%
Heparin plasma(n=5) 84-103% 96%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of MIg and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 88-97% 91-98% 86-103% 79-91%
EDTA plasma(n=5) 85-104% 87-106% 83-92% 82-90%
Heparin plasma(n=5) 85-102% 79-92% 87-103% 89-98%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
阿克苏市| 吉林省| 井冈山市| 马公市| 四川省| 桦川县| 宿州市| 上蔡县| 兴文县| 两当县| 应用必备| 阳城县| 苏尼特右旗| 杭锦后旗| 鹤壁市| 玉环县| 合作市| 南岸区| 启东市| 泰和县| 开远市| 阜平县| 建宁县| 临汾市| 泰兴市| 汽车| 涟源市| 天津市| 军事| 库尔勒市| 湘乡市| 侯马市| 宜章县| 克东县| 兴城市| 临澧县| 荣昌县| 剑阁县| 灵石县| 宜城市| 务川|