免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人組織蛋白酶V(CTSV)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1342
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human CTSV(Cathepsin V) ELISA Kit
Reactivity: Human
Alternative Names: CTS-L2; CTSL2; CATL2; CTSU; CTS-V; Cathepsin L2
Assay Type: Sandwich
Sensitivity: 0.057 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: tissue homogenates, cell lysates and other biological fluids
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Tumor immunity;Dermatology;
Uniprot ID: O60911
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human CTSV. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human CTSV. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human CTSV, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human CTSV in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
10.00 1.997 1.889
5.00 1.608 1.500
2.50 1.277 1.169
1.25 0.935 0.827
0.63 0.596 0.488
0.32 0.379 0.271
0.16 0.226 0.118
0.00 0.108 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CTSV and the recovery rates were calculated by comparing the measured value to the expected amount of CTSV in samples.
Matrix Recovery range Average
serum(n=5) 92-106% 99%
EDTA plasma(n=5) 88-103% 95%
Heparin plasma(n=5) 80-97% 88%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CTSV and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 88-97% 96-105% 81-96% 93-107%
EDTA plasma(n=5) 85-94% 87-96% 92-101% 82-95%
Heparin plasma(n=5) 95-102% 83-96% 97-105% 85-97%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
临泉县| 张家港市| 公主岭市| 鄂尔多斯市| 龙岩市| 柳林县| 博客| 绍兴市| 拜泉县| 乌兰县| 恩平市| 吴堡县| 高平市| 如东县| 沁阳市| 赤水市| 资兴市| 全州县| 夏津县| 孙吴县| 璧山县| 莆田市| 元谋县| 永靖县| 遵义县| 桃园县| 建始县| 萨迦县| 烟台市| 新平| 阳曲县| 无棣县| 呼伦贝尔市| 安庆市| 亳州市| 阜康市| 新宁县| 宁武县| 福鼎市| 东安县| 天峨县|