免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人干擾素誘導(dǎo)T-細胞α亞族趨化劑(ITaC)酶聯(lián)免疫吸附檢測試劑盒
ELK1344
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human ITaC(Interferon Inducible T-Cell Alpha Chemoattractant) ELISA Kit
Reactivity: Human
Alternative Names: CXCL11; I-TAC; IP9; SCYB11; SCYB9B; B-R1; Chemokine(C-X-C-Motif)ligand 11; Small Inducible Cytokine Subfamily B Member 11; Interferon gamma-inducible protein 9
Assay Type: Sandwich
Sensitivity: 24.2 pg/mL
Standard: 4000 pg/mL
Detection Range: 62.5-4000 pg/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Signal transduction;Infection immunity;
Uniprot ID: O14625
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human ITaC. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human ITaC. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human ITaC, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human ITaC in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
4000.00 1.954 1.867
2000.00 1.653 1.566
1000.00 1.276 1.189
500.00 0.943 0.856
250.00 0.623 0.536
125.00 0.354 0.267
62.50 0.227 0.140
0.00 0.087 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant ITaC and the recovery rates were calculated by comparing the measured value to the expected amount of ITaC in samples.
Matrix Recovery range Average
serum(n=5) 82-94% 88%
EDTA plasma(n=5) 94-105% 98%
Heparin plasma(n=5) 83-97% 91%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of ITaC and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 95-103% 91-105% 78-90% 89-97%
EDTA plasma(n=5) 85-94% 87-96% 82-93% 89-103%
Heparin plasma(n=5) 85-92% 83-101% 87-98% 79-92%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
应城市| 达孜县| 德江县| 博罗县| 乌苏市| 邯郸县| 岳池县| 玉溪市| 江永县| 安仁县| 那坡县| 洱源县| 西丰县| 周宁县| 枣强县| 藁城市| 石泉县| 比如县| 定日县| 乌海市| 同心县| 双辽市| 沙湾县| 三门峡市| 新营市| 津南区| 三穗县| 滕州市| 方山县| 淮安市| 苗栗市| 建平县| 灌南县| 乐亭县| 石渠县| 仁怀市| 乳山市| 巢湖市| 安康市| 惠州市| 南宁市|