免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠血紅蛋白(HB)酶聯(lián)免疫吸附檢測試劑盒
ELK1354
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Mouse HB(Hemoglobin) ELISA Kit
Reactivity: Mouse
Alternative Names: Hgb; Haemoglobin; Heterotetramer(αβ)2
Assay Type: Sandwich
Sensitivity: 0.24 ng/mL
Standard: 400 ng/mL
Detection Range: 6.25-400 ng/mL
Sample Type: serum, plasma and erythrocyte lysates
Assay Length: 3.5h
Research Area: Metabolic pathway;Infection immunity;Hematology;Neuro science;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse HB. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse HB. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse HB, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse HB in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
400.00 2.185 2.087
200.00 1.527 1.429
100.00 1.196 1.098
50.00 0.852 0.754
25.00 0.529 0.431
12.50 0.308 0.210
6.25 0.214 0.116
0.00 0.098 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant HB and the recovery rates were calculated by comparing the measured value to the expected amount of HB in samples.
Matrix Recovery range Average
serum(n=5) 87-99% 93%
EDTA plasma(n=5) 81-95% 88%
Heparin plasma(n=5) 87-99% 93%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of HB and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 88-99% 86-92% 89-103% 97-105%
EDTA plasma(n=5) 95-104% 87-96% 82-96% 89-103%
Heparin plasma(n=5) 85-92% 89-96% 90-98% 87-98%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
武安市| 库车县| 鹤山市| 乐清市| 神农架林区| 囊谦县| 桃园县| 杭锦旗| 上林县| 河间市| 奎屯市| 遵义县| 景宁| 宝清县| 廉江市| 库伦旗| 灵武市| 浮山县| 攀枝花市| 永靖县| 盐边县| 伊川县| 石门县| 嘉定区| 新沂市| 新乡市| 涞源县| 林西县| 吉木乃县| 开鲁县| 金门县| 宿迁市| 黎平县| 贞丰县| 思南县| 扶沟县| 中西区| 广丰县| 韶山市| 弥勒县| 桦甸市|