免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

牛堿性磷酸酶(ALP)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1355
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Cattle ALP(Alkaline Phosphatase) ELISA Kit
Reactivity: Cattle
Alternative Names: AKP; ALKP; Basic Phosphatase
Assay Type: Sandwich
Sensitivity: 0.066 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Metabolic pathway;Tumor immunity;Infection immunity;Hepatology;Bone metabolism;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Cattle ALP. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Cattle ALP. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Cattle ALP, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Cattle ALP in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.052 1.944
5.00 1.755 1.647
2.50 1.069 0.961
1.25 0.812 0.704
0.63 0.507 0.399
0.32 0.352 0.244
0.16 0.248 0.140
0.00 0.108 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant ALP and the recovery rates were calculated by comparing the measured value to the expected amount of ALP in samples.
Matrix Recovery range Average
serum(n=5) 83-95% 89%
EDTA plasma(n=5) 96-107% 102%
Heparin plasma(n=5) 85-99% 92%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of ALP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 88-97% 86-92% 79-103% 89-97%
EDTA plasma(n=5) 85-94% 97-106% 79-91% 90-99%
Heparin plasma(n=5) 85-102% 81-96% 87-105% 83-92%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
都昌县| 鄢陵县| 昌黎县| 信丰县| 大化| 三门县| 陆良县| 诸城市| 临西县| 宁陵县| 庆阳市| 四子王旗| 青阳县| 牙克石市| 黔西| 微山县| 巨鹿县| 汤原县| 安平县| 和田市| 灵宝市| 西宁市| 宜君县| 泰宁县| 凉山| 岑溪市| 六安市| 靖远县| 伊宁县| 宽甸| 常德市| 万安县| 乡城县| 宜州市| 廉江市| 新营市| 碌曲县| 开平市| 尚义县| 定陶县| 竹溪县|