免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠S100鈣結(jié)合蛋白A6(S100A6)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1359
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Mouse S100A6(S100 Calcium Binding Protein A6) ELISA Kit
Reactivity: Mouse
Alternative Names: S100-A6; 2A9; 5B10; CABP; CACY; PRA; MLN 4; Calcyclin; Growth factor-inducible protein 2A9; Prolactin receptor-associated protein
Assay Type: Sandwich
Sensitivity: 5.8 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Tumor immunity;Infection immunity;Hematology;Dermatology;
Uniprot ID: P14069
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse S100A6. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse S100A6. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse S100A6, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse S100A6 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線(xiàn)

Concentration (pg/mL) OD Corrected OD
1000.00 2.164 2.077
500.00 1.699 1.612
250.00 1.135 1.048
125.00 0.886 0.799
62.50 0.543 0.456
31.25 0.388 0.301
15.63 0.248 0.161
0.00 0.087 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant S100A6 and the recovery rates were calculated by comparing the measured value to the expected amount of S100A6 in samples.
Matrix Recovery range Average
serum(n=5) 95-107% 101%
EDTA plasma(n=5) 80-93% 86%
Heparin plasma(n=5) 80-95% 87%

線(xiàn)性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of S100A6 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 78-96% 89-102% 85-97% 79-97%
EDTA plasma(n=5) 92-104% 87-96% 89-101% 82-90%
Heparin plasma(n=5) 85-92% 82-96% 87-103% 95-102%
關(guān)閉

在線(xiàn)咨詢(xún)

Online consultation

  • 在線(xiàn)咨詢(xún)
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢(xún)

微信掃一掃立即咨詢(xún)

關(guān)閉
固始县| 河源市| 澄江县| 富顺县| 鹤峰县| 南昌县| 文山县| 双牌县| 和平县| 新昌县| 长武县| 江阴市| 景德镇市| 武清区| 通道| 谢通门县| 恭城| 理塘县| 平利县| 兴义市| 徐州市| 庆城县| 德兴市| 边坝县| 柞水县| 康保县| 临江市| 大庆市| 宣威市| 唐海县| 贵溪市| 江陵县| 兴仁县| 察隅县| 江口县| 金溪县| 伊川县| 涿州市| 湖北省| 巩留县| 肇源县|