免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人S100鈣結(jié)合蛋白A10(S100A10)酶聯(lián)免疫吸附檢測(cè)試劑盒
ELK1361
規(guī)格: 價(jià)格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human S100A10(S100 Calcium Binding Protein A10) ELISA Kit
Reactivity: Human
Alternative Names: ANX2L; ANX2LG; CAL1L; CLP11; GP11; P11; P10; Calpactin-1 light chain; Cellular ligand of annexin II; Annexin II Ligand,Calpactin I,Light Polypeptide
Assay Type: Sandwich
Sensitivity: 0.063 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Signal transduction;Tumor immunity;Neuro science;
Uniprot ID: P60903
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human S100A10. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human S100A10. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human S100A10, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human S100A10 in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.219 2.132
5.00 1.643 1.556
2.50 1.154 1.067
1.25 0.896 0.809
0.63 0.498 0.411
0.32 0.364 0.277
0.16 0.206 0.119
0.00 0.087 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant S100A10 and the recovery rates were calculated by comparing the measured value to the expected amount of S100A10 in samples.
Matrix Recovery range Average
serum(n=5) 87-99% 93%
EDTA plasma(n=5) 93-107% 100%
Heparin plasma(n=5) 87-95% 91%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of S100A10 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 88-97% 86-92% 95-103% 98-106%
EDTA plasma(n=5) 95-102% 87-101% 82-91% 85-97%
Heparin plasma(n=5) 93-102% 78-92% 87-98% 80-93%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
榆树市| 青田县| 伊宁县| 南阳市| 南靖县| 银川市| 榕江县| 沈阳市| 衡山县| 屏东市| 都安| 镇坪县| 定陶县| 大石桥市| 康马县| 红安县| 集安市| 克拉玛依市| 郴州市| 祁门县| 武威市| 嘉峪关市| 吉林省| 古浪县| 繁峙县| 宁河县| 瑞安市| 鲁山县| 广东省| 南溪县| 铜川市| 东源县| 高邑县| 南华县| 大宁县| 大兴区| 滨海县| 沛县| 淮安市| 牙克石市| 宁阳县|