免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產品中心

人腎腫瘤抗原(RAGE)酶聯(lián)免疫吸附檢測試劑盒
ELK1369
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Human RAGE(Renal Tumor Antigen) ELISA Kit
Reactivity: Human
Alternative Names: MOK; RAGE1; MAPK/MAK/MRK Overlapping Kinase
Assay Type: Sandwich
Sensitivity: 0.062 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: tissue homogenates, cell lysates and other biological fluids
Assay Length: 3.5h
Research Area: Tumor immunity;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human RAGE. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human RAGE. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human RAGE, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human RAGE in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
10.00 1.941 1.860
5.00 1.554 1.473
2.50 1.182 1.101
1.25 0.823 0.742
0.63 0.532 0.451
0.32 0.335 0.254
0.16 0.176 0.095
0.00 0.081 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant RAGE and the recovery rates were calculated by comparing the measured value to the expected amount of RAGE in samples.
Matrix Recovery range Average
serum(n=5) 80-92% 86%
EDTA plasma(n=5) 88-102% 95%
Heparin plasma(n=5) 90-105% 97%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of RAGE and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 79-97% 96-104% 85-93% 89-97%
EDTA plasma(n=5) 85-94% 87-96% 92-105% 89-102%
Heparin plasma(n=5) 85-102% 78-92% 87-98% 95-102%
關閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術支持

關注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關閉
通化县| 遂平县| 台南县| 钦州市| 应城市| 铜陵市| 麟游县| 墨玉县| 牡丹江市| 灌阳县| 利辛县| 威海市| 渑池县| 志丹县| 丽江市| 刚察县| 方山县| 涟水县| 嘉鱼县| 舞钢市| 会宁县| 孝感市| 湾仔区| 壶关县| 大连市| 临高县| 通道| 霍州市| 汝城县| 利津县| 湾仔区| 瑞昌市| 都江堰市| 申扎县| 阳泉市| 和田市| 普兰店市| 天祝| 罗江县| 株洲市| 迁安市|