免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

小鼠趨化素(CHEM)酶聯(lián)免疫吸附檢測試劑盒
ELK1376
規(guī)格: 價格:
48T ¥1680.00
96T ¥2400.00

Overview

Product name: Mouse CHEM(Chemerin) ELISA Kit
Reactivity: Mouse
Alternative Names: TIG2; RARRES2; Tazarotene-Induced Gene 2; Retinoic Acid Receptor Responder 2,Tazarotene Induced; RAR-responsive protein TIG2
Assay Type: Sandwich
Sensitivity: 0.32 ng/mL
Standard: 50 ng/mL
Detection Range: 0.79-50 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Metabolic pathway;Infection immunity;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Mouse CHEM. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse CHEM. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Mouse CHEM, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse CHEM in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
50.00 2.270 2.187
25.00 1.877 1.794
12.50 1.194 1.111
6.25 0.831 0.748
3.13 0.587 0.504
1.57 0.357 0.274
0.79 0.252 0.169
0.00 0.083 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CHEM and the recovery rates were calculated by comparing the measured value to the expected amount of CHEM in samples.
Matrix Recovery range Average
serum(n=5) 80-93% 86%
EDTA plasma(n=5) 93-107% 100%
Heparin plasma(n=5) 87-99% 93%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CHEM and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 85-96% 86-98% 92-103% 87-93%
EDTA plasma(n=5) 81-94% 85-97% 93-102% 81-95%
Heparin plasma(n=5) 78-92% 82-96% 86-99% 93-101%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
中西区| 红原县| 马龙县| 普陀区| 泰顺县| 黄龙县| 丹巴县| 金沙县| 柯坪县| 白城市| 望谟县| 德安县| 南陵县| 伊宁县| 漾濞| 临沭县| 铜梁县| 五常市| 福州市| 金沙县| 察隅县| 玛曲县| 武邑县| 潞西市| 西充县| 巨野县| 肇州县| 浏阳市| 井陉县| 青冈县| 宣威市| 三亚市| 新竹县| 汶上县| 麻栗坡县| 灌南县| 揭阳市| 华安县| 巴中市| 莲花县| 渭源县|