免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人趨化因子C-C-基元配體3樣蛋白1(CCL3L1)酶聯(lián)免疫吸附檢測試劑盒
ELK1413
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human CCL3L1(Chemokine C-C-Motif Ligand 3 Like Protein 1) ELISA Kit
Reactivity: Human
Alternative Names: CCL3-L1; LD78; SCYA3L; SCYA3L1; MIP1AP; MIP1-Alpha-P; Small Inducible Cytokine A3-Like 1; Macrophage Inflammatory Protein 1-Alpha-P; Tonsillar Lymphocyte LD78 Beta
Assay Type: Sandwich
Sensitivity: 0.057 ng/mL
Standard: 10 ng/mL
Detection Range: 0.16-10 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length: 3.5h
Research Area: Cytokine;Infection immunity;Immune molecule;
Uniprot ID: P16619
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human CCL3L1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human CCL3L1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human CCL3L1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human CCL3L1 in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (ng/mL) OD Corrected OD
10.00 2.035 1.940
5.00 1.617 1.522
2.50 1.175 1.080
1.25 0.895 0.800
0.63 0.556 0.461
0.32 0.363 0.268
0.16 0.258 0.163
0.00 0.095 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant CCL3L1 and the recovery rates were calculated by comparing the measured value to the expected amount of CCL3L1 in samples.
Matrix Recovery range Average
serum(n=5) 79-97% 88%
EDTA plasma(n=5) 83-95% 89%
Heparin plasma(n=5) 88-102% 95%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CCL3L1 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 89-97% 85-94% 79-96% 85-99%
EDTA plasma(n=5) 79-93% 89-97% 85-94% 87-101%
Heparin plasma(n=5) 86-94% 85-95% 89-99% 85-95%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
晋州市| 汉寿县| 遂溪县| 清水县| 乌拉特中旗| 江北区| 仙桃市| 河曲县| 山阴县| 塔河县| 郓城县| 高唐县| 电白县| 密云县| 乌鲁木齐市| 敦煌市| 霍林郭勒市| 理塘县| 阜新市| 隆德县| 盐池县| 乌兰浩特市| 平果县| 浠水县| 弥渡县| 陇西县| 普兰店市| 苗栗市| 石台县| 铜梁县| 分宜县| 公主岭市| 中方县| 广宗县| 海宁市| 桓仁| 麻城市| 东乌珠穆沁旗| 临安市| 延津县| 沐川县|