免费久久无码精品一区二区,国产AV一区二区最新精品无删减,欧美久久男人的天堂,免费国产小视频国产

產(chǎn)品中心

人甲狀腺過氧化物酶(TPO)酶聯(lián)免疫吸附檢測試劑盒
ELK1451
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human TPO(Thyroid Peroxidase) ELISA Kit
Reactivity: Human
Alternative Names: TPX; thyroperoxidase
Assay Type: Sandwich
Sensitivity: 0.112 ng/mL
Standard: 20 ng/mL
Detection Range: 0.32-20 ng/mL
Sample Type: Tissue homogenates and other biological fluids.
Assay Length: 3.5h
Research Area: Enzyme & Kinase;Endocrinology;Hormone metabolism;
Uniprot ID: P07202
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human TPO. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human TPO. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human TPO, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human TPO in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (ng/mL) OD Corrected OD
20.00 2.035 1.950
10.00 1.717 1.632
5.00 1.185 1.100
2.50 0.796 0.711
1.25 0.582 0.497
0.63 0.363 0.278
0.32 0.258 0.173
0.00 0.085 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant TPO and the recovery rates were calculated by comparing the measured value to the expected amount of TPO in samples.
Matrix Recovery range Average
serum(n=5) 81-97% 89%
EDTA plasma(n=5) 84-99% 91%
Heparin plasma(n=5) 79-91% 85%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of TPO and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 95-103% 87-98% 85-92% 79-96%
EDTA plasma(n=5) 86-96% 85-97% 89-101% 85-97%
Heparin plasma(n=5) 89-97% 85-94% 79-96% 85-99%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉
嘉祥县| 浦北县| 晋宁县| 江都市| 卢氏县| 项城市| 策勒县| 子洲县| 锡林郭勒盟| 瑞安市| 务川| 通海县| 正阳县| 铁岭县| 溧阳市| 福建省| 凤翔县| 石狮市| 资兴市| 合阳县| 乡宁县| 沧源| 曲靖市| 阳高县| 东丽区| 巩留县| 来安县| 吴桥县| 定州市| 金乡县| 武强县| 四子王旗| 沙河市| 南开区| 海城市| 乌恰县| 新河县| 临潭县| 雷波县| 宁陵县| 隆林|